← Colorado

Tap water quality report

Lafayette, CO

EPA monitoring detected 24 contaminants across the 7 water suppliers serving Lafayette. A detection doesn't automatically mean the water is unsafe — see the level at the main supplier for each below, with its EPA source and period.

7
water suppliers
31,794
people served
24
contaminants found

What was found in Lafayette's water

The level at the city's main supplier, the highest level anywhere in the city, the EPA limit for each, and where every figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Nitrate
76 µg/L 0.8%
of the EPA limit 10000 µg/L
Main supplier: LAFAYETTE CITY OF · 28,700 people · 2019
Highest in the city: 1900 µg/L — SAN LAZARO MFCTD HOUSING COMMUNITY · 844 people · 2019
4/7 SYR4
Fluoride
1014.5 µg/L 25%
of the EPA limit 4000 µg/L
Main supplier: LAFAYETTE CITY OF · 28,700 people · 2019
Highest in the city: 1085 µg/L — LARK MEADOWS WA · 75 people · 2019
4/7 SYR4
Nitrate-Nitrite
75.5 µg/L 0.8%
of the EPA limit 10000 µg/L
Main supplier: LAFAYETTE CITY OF · 28,700 people · 2013
Highest in the city: 1000 µg/L — SAN LAZARO MFCTD HOUSING COMMUNITY · 844 people · 2013
4/7 SYR4
Barium
49.25 µg/L 2.5%
of the EPA limit 2000 µg/L
Main supplier: LAFAYETTE CITY OF · 28,700 people · 2019
Highest in the city: 143.25 µg/L — SAN LAZARO MFCTD HOUSING COMMUNITY · 844 people · 2019
4/7 SYR4
TTHM
85.555 µg/L 107%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
Main supplier: LAFAYETTE CITY OF · 28,700 people · 2019
4/7 SYR4
Chloroform
45.54 µg/L
No EPA limit set
Main supplier: LAFAYETTE CITY OF · 28,700 people · 2019
4/7 SYR4
Total Haloacetic Acids (HAA5)
32.915 µg/L 55%
of the EPA limit 60 µg/L
Main supplier: LAFAYETTE CITY OF · 28,700 people · 2019
4/7 SYR4
Nitrite
22 µg/L 2.2%
of the EPA limit 1000 µg/L
Highest in the city: MAPLE GROVE WD · 35 people · 2012
2/7 SYR4
Bromodichloromethane
20.82 µg/L
No EPA limit set
Main supplier: LAFAYETTE CITY OF · 28,700 people · 2019
4/7 SYR4
Dichloroacetic Acid
15.414 µg/L
No EPA limit set
Main supplier: LAFAYETTE CITY OF · 28,700 people · 2019
2/7 SYR4
Dibromochloromethane
9.08 µg/L
No EPA limit set
Main supplier: LAFAYETTE CITY OF · 28,700 people · 2019
Highest in the city: 14.465 µg/L — SAN LAZARO MFCTD HOUSING COMMUNITY · 844 people · 2019
4/7 SYR4
Trichloroacetic Acid
8.7285 µg/L
No EPA limit set
Main supplier: LAFAYETTE CITY OF · 28,700 people · 2019
2/7 SYR4
Selenium
0.9900 µg/L 2%
of the EPA limit 50 µg/L
Main supplier: LAFAYETTE CITY OF · 28,700 people · 2019
Highest in the city: 7.8 µg/L — SAN LAZARO MFCTD HOUSING COMMUNITY · 844 people · 2019
2/7 SYR4
Bromoform
1.3 µg/L
No EPA limit set
Main supplier: LAFAYETTE CITY OF · 28,700 people · 2019
Highest in the city: 5.92 µg/L — SAN LAZARO MFCTD HOUSING COMMUNITY · 844 people · 2019
4/7 SYR4
Dibromoacetic Acid
2.87 µg/L
No EPA limit set
Main supplier: LAFAYETTE CITY OF · 28,700 people · 2019
Highest in the city: 4.81 µg/L — SAN LAZARO MFCTD HOUSING COMMUNITY · 844 people · 2019
3/7 SYR4
Gross Alpha, Excl. Radon And U
3.065 pCi/L 20%
of the EPA limit 15 pCi/L
Highest in the city: LARK MEADOWS WA · 75 people · 2014
1/7 SYR4
Chromium
1 µg/L 1%
of the EPA limit 100 µg/L
Main supplier: LAFAYETTE CITY OF · 28,700 people · 2019
Highest in the city: 2.95 µg/L — SAN LAZARO MFCTD HOUSING COMMUNITY · 844 people · 2019
3/7 SYR4
Antimony, Total
2.9 µg/L 48%
of the EPA limit 6 µg/L
Highest in the city: SAN LAZARO MFCTD HOUSING COMMUNITY · 844 people · 2019
1/7 SYR4
Combined Uranium
2.495 µg/L 8.3%
of the EPA limit 30 µg/L
Highest in the city: LARK MEADOWS WA · 75 people · 2019
2/7 SYR4
Monobromoacetic Acid
1.3 µg/L
No EPA limit set
Main supplier: LAFAYETTE CITY OF · 28,700 people · 2019
Highest in the city: 2.25 µg/L — SAN LAZARO MFCTD HOUSING COMMUNITY · 844 people · 2019
2/7 SYR4
Monochloroacetic Acid
2.085 µg/L
No EPA limit set
Main supplier: LAFAYETTE CITY OF · 28,700 people · 2019
3/7 SYR4
Arsenic
2 µg/L 20%
of the EPA limit 10 µg/L
Highest in the city: MAPLE GROVE WD · 35 people · 2018
2/7 SYR4
Combined Radium (-226 And -228)
0.6000 pCi/L 12%
of the EPA limit 5 pCi/L
Highest in the city: LARK MEADOWS WA · 75 people · 2012
3/7 SYR4
Lead
0.0020 mg/L 13%
of the EPA limit 0.0150 mg/L
Main supplier: LAFAYETTE CITY OF · 28,700 people · 2025
Highest in the city: 0.0100 mg/L — LARK MEADOWS WA · 75 people · 2025
7/7 LCR
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of the system's samples — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately. These are the utilities' own EPA-reported results, not a city-wide average. A detection means the lab measured the substance — it isn't the same as exceeding a legal limit. Hover a source tag to see the EPA program and years behind each figure.

Water suppliers serving Lafayette

Frequently asked questions about Lafayette tap water

Is Lafayette tap water safe to drink?

EPA testing detected 24 contaminants in the water serving Lafayette. A detection isn't the same as a violation — most detected levels are within federal limits. Check the level and source for each contaminant above, and your utility's annual Consumer Confidence Report for the official compliance status.

How many water suppliers serve Lafayette?

7 public water suppliers report drinking-water monitoring for Lafayette, Colorado to the EPA. Each is listed above with its population served.

What contaminants are in Lafayette's water?

The contaminants EPA monitoring detected in Lafayette include Nitrate, Fluoride, Nitrate-Nitrite, Barium, TTHM. The full list, with the level at the main supplier and the data source, is in the table above.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.