EPA monitoring detected 29 contaminants across the 2 water suppliers serving Chino. A detection doesn't automatically mean the water is unsafe — see the level at the main supplier for each below, with its EPA source and period.

2
water suppliers
97,102
people served
29
contaminants found

What was found in Chino's water

The level at the city's main supplier, the highest level anywhere in the city, the EPA limit for each, and where every figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Nitrate
49720 µg/L 497%
of the EPA limit, at the 95th percentile of samples — 10000 µg/L
Main supplier: CHINO, CITY OF · 86,435 people · 2019
2/2 SYR4
Nitrate-Nitrite
26000 µg/L 260%
of the EPA limit, at the 95th percentile of samples — 10000 µg/L
Main supplier: CHINO, CITY OF · 86,435 people · 2017
2/2 SYR4
Fluoride
240 µg/L 6%
of the EPA limit 4000 µg/L
Main supplier: CHINO, CITY OF · 86,435 people · 2018
2/2 SYR4
Barium
170 µg/L 8.5%
of the EPA limit 2000 µg/L
Main supplier: CHINO, CITY OF · 86,435 people · 2018
2/2 SYR4
Copper
78.99 µg/L 6.1%
of the EPA limit 1300 µg/L
Highest in the city: CALIFORNIA INSTITUTION FOR MEN · 10,667 people · 2019
1/2 SYR4
TTHM
66 µg/L 83%
of the EPA limit 80 µg/L
Main supplier: CHINO, CITY OF · 86,435 people · 2019
2/2 SYR4
Dibromochloromethane
26 µg/L
No EPA limit set
Main supplier: CHINO, CITY OF · 86,435 people · 2019
2/2 SYR4
Bromoform
25 µg/L
No EPA limit set
Main supplier: CHINO, CITY OF · 86,435 people · 2019
2/2 SYR4
Total Haloacetic Acids (HAA5)
12 µg/L 20%
of the EPA limit 60 µg/L
Main supplier: CHINO, CITY OF · 86,435 people · 2019
Highest in the city: 22.35 µg/L — CALIFORNIA INSTITUTION FOR MEN · 10,667 people · 2019
2/2 SYR4
Monochloroacetic Acid
21.06 µg/L
No EPA limit set
Highest in the city: CALIFORNIA INSTITUTION FOR MEN · 10,667 people · 2019
1/2 SYR4
Chloroform
21 µg/L
No EPA limit set
Main supplier: CHINO, CITY OF · 86,435 people · 2019
1/2 SYR4
Bromodichloromethane
18 µg/L
No EPA limit set
Main supplier: CHINO, CITY OF · 86,435 people · 2019
1/2 SYR4
Chromium
12.85 µg/L 13%
of the EPA limit 100 µg/L
Main supplier: CHINO, CITY OF · 86,435 people · 2018
2/2 SYR4
Selenium
11.53 µg/L 23%
of the EPA limit 50 µg/L
Highest in the city: CALIFORNIA INSTITUTION FOR MEN · 10,667 people · 2019
1/2 SYR4
Combined Uranium
8.8357 µg/L 29%
of the EPA limit 30 µg/L
Main supplier: CHINO, CITY OF · 86,435 people · 2018
1/2 SYR4
Dibromoacetic Acid
6.445 µg/L
No EPA limit set
Main supplier: CHINO, CITY OF · 86,435 people · 2019
2/2 SYR4
Dichloroacetic Acid
5.695 µg/L
No EPA limit set
Main supplier: CHINO, CITY OF · 86,435 people · 2019
2/2 SYR4
Arsenic
4.23 µg/L 42%
of the EPA limit 10 µg/L
Main supplier: CHINO, CITY OF · 86,435 people · 2018
2/2 SYR4
Trichloroacetic Acid
4.04 µg/L
No EPA limit set
Main supplier: CHINO, CITY OF · 86,435 people · 2019
2/2 SYR4
Tetrachloroethylene
3.285 µg/L 66%
of the EPA limit 5 µg/L
Highest in the city: CALIFORNIA INSTITUTION FOR MEN · 10,667 people · 2019
1/2 SYR4
Picloram
2.095 µg/L 0.4%
of the EPA limit 500 µg/L
Main supplier: CHINO, CITY OF · 86,435 people · 2018
1/2 SYR4
Trichloroethylene
1.765 µg/L 35%
of the EPA limit 5 µg/L
Main supplier: CHINO, CITY OF · 86,435 people · 2018
2/2 SYR4
Cadmium
1.71 µg/L 34%
of the EPA limit 5 µg/L
Highest in the city: CALIFORNIA INSTITUTION FOR MEN · 10,667 people · 2019
1/2 SYR4
Mercury
1.7 µg/L 85%
of the EPA limit 2 µg/L
Highest in the city: CALIFORNIA INSTITUTION FOR MEN · 10,667 people · 2019
1/2 SYR4
Monobromoacetic Acid
1.36 µg/L
No EPA limit set
Main supplier: CHINO, CITY OF · 86,435 people · 2019
2/2 SYR4
Nitrite
0.9340 µg/L 0.1%
of the EPA limit 1000 µg/L
Highest in the city: CALIFORNIA INSTITUTION FOR MEN · 10,667 people · 2018
1/2 SYR4
Asbestos
0.1980 MFL 2.8%
of the EPA limit 7 MFL
Highest in the city: CALIFORNIA INSTITUTION FOR MEN · 10,667 people · 2012
1/2 SYR4
1,2-DIBROMO-3-CHLOROPROPANE
0.0808 µg/L 40%
of the EPA limit 0.2000 µg/L
Main supplier: CHINO, CITY OF · 86,435 people · 2018
1/2 SYR4
Lead
0.0010 mg/L 6.7%
of the EPA limit 0.0150 mg/L
Main supplier: CHINO, CITY OF · 86,435 people · 2024
2/2 LCR
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of the system's samples — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately. These are the utilities' own EPA-reported results, not a city-wide average. A detection means the lab measured the substance — it isn't the same as exceeding a legal limit. Hover a source tag to see the EPA program and years behind each figure.

Water suppliers serving Chino

SupplierPopulation served
CHINO, CITY OF 86,435
CALIFORNIA INSTITUTION FOR MEN 10,667

Frequently asked questions about Chino tap water

Is Chino tap water safe to drink?

EPA testing detected 29 contaminants in the water serving Chino. A detection isn't the same as a violation — most detected levels are within federal limits. Check the level and source for each contaminant above, and your utility's annual Consumer Confidence Report for the official compliance status.

How many water suppliers serve Chino?

2 public water suppliers report drinking-water monitoring for Chino, California to the EPA. Each is listed above with its population served.

What contaminants are in Chino's water?

The contaminants EPA monitoring detected in Chino include Nitrate, Nitrate-Nitrite, Fluoride, Barium, Copper. The full list, with the level at the main supplier and the data source, is in the table above.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.